Federal Register - August 10, 2021

Versión en texto ¿Qué es?Dateas es un sitio independiente no afiliado a entidades gubernamentales. La fuente de los documentos PDF aquí publicados es la entidad gubernamental indicada en cada uno de ellos. Las versiones en texto son transcripciones no oficiales que realizamos para facilitar el acceso y la búsqueda de información, pero pueden contener errores o no estar completas.

Fuente: Federal Register

43642

Federal Register / Vol. 86, No. 151 / Tuesday, August 10, 2021 / Notices
TABLE 16-FREEZER UNIT COOLER

Unit cooler air entering Test dry-bulb, OF
description
Unit cooler air entering Liquid Liquid relative Saturated inlet inlet humidity, suction saturation subcooling %
temp, F temp, F temp, F

Off Cycle Fan Power
-10

<50

Refrigeration Capacity Suction A

-10

<50

Defrost
-10

Various
-

-

-20

-

-

Test objective
Compressor Off Measure fan input power during compressor off cycle.

-

5

38

Compressor capacity
-

Compressor On
Determine Net Refrigeration Capacity of !Unit Cooler.

Compressor Off Test according to k<.ppendix C
Section Cl 1.

3 Representations. RefPlus may not make representations about the energy efficiency of a basic model listed in paragraph 1 for compliance, marketing, or other purposes unless that basic model has been tested in accordance with the provisions set forth in this alternate test procedure and such representations fairly disclose the results of such testing.
4 This Interim Waiver Order shall remain in effect according to the provisions of 10 CFR 431.401.
5 This Interim Waiver Order is issued on the condition that the statements, representations, test data, and documentary materials provided by RefPlus are valid. If RefPlus makes any modifications to the controls or configurations of a basic model subject to this Interim Waiver Order, such modifications will render the waiver invalid with respect to that basic model, and RefPlus will either be required to use the current Federal test method or submit a new application for a test procedure waiver. DOE may rescind or modify this waiver at any time if it
VerDate Sep<11>2014

17:05 Aug 09, 2021

Jkt 253001

determines the factual basis underlying the petition for the Interim Waiver Order is incorrect, or the results from the alternate test procedure are unrepresentative of the basic models true energy consumption characteristics.
10 CFR 431.401k1. Likewise, RefPlus may request that DOE rescind or modify the Interim Waiver Order if RefPlus discovers an error in the information provided to DOE as part of its petition, determines that the interim waiver is no longer needed, or for other appropriate reasons. 10 CFR 431.401k2.
6 Issuance of this Interim Waiver Order does not release RefPlus from the applicable requirements set forth at 10
CFR part 429.
DOE makes decisions on waivers and interim waivers for only those basic models specifically set out in the petition, not future models that may be manufactured by the petitioner. RefPlus may submit a new or amended petition for waiver and request for grant of interim waiver, as appropriate, for additional basic models of CO2 direct expansion unit coolers. Alternatively, if
PO 00000

Frm 00019

Fmt 4703

Sfmt 4703

appropriate, RefPlus may request that DOE extend the scope of a waiver or an interim waiver to include additional basic models employing the same technology as the basic models set forth in the original petition consistent with 10 CFR 431.401g.
Signing Authority This document of the Department of Energy was signed on August 3, 2021, by Kelly Speakes-Backman, Principal Deputy Assistant Secretary and Acting Assistant Secretary for Energy Efficiency and Renewable Energy, pursuant to delegated authority from the Secretary of Energy. That document with the original signature and date is maintained by DOE. For administrative purposes only, and in compliance with requirements of the Office of the Federal Register, the undersigned DOE Federal Register Liaison Officer has been authorized to sign and submit the document in electronic format for publication, as an official document of the Department of Energy. This administrative process in no way alters
E:FRFM10AUN1.SGM

10AUN1

EN10AU21.014

jbell on DSKJLSW7X2PROD with NOTICES

Note: Superheat to be set according to equipment specification in equipment or installation manual. If no superheat specification is given, a default superheat value of 6.5 F shall be used.
The superheat setting used in the test shall be reported as part of the standard rating.

Acerca de esta edición

Federal Register - August 10, 2021

TítuloFederal Register

PaísEstados Unidos de América

Fecha10/08/2021

Nro. de páginas325

Nro. de ediciones7798

Primera edición14/03/1936

Ultima edición18/06/2026

Descargar esta edición

Otras ediciones

<<<Agosto 2021>>>
DLMMJVS
1234567
891011121314
15161718192021
22232425262728
293031