Versione di testo Cosa è?Dateas è un sito indipendente non affiliato a entità governative. La fonte dei documenti PDF che pubblichiamo qui è l'entità governativa indicata in ciascuno di essi. Le versioni in testo sono trascrizioni che realizziamo per facilitare l'accesso e la ricerca di informazioni, ma possono contenere errori o non essere complete.
Source: Federal Register
72144
Federal Register / Vol. 86, No. 241 / Monday, December 20, 2021 / Proposed Rules
C. Calculating the circulator energy rating.
Determine the CER of each tested circulator pump using the following equation:
CER =
L w/Pin,D
i
C. Calculating the circulator energy rating.
Determine the CER of each tested circulator pump using the following equation:
CER
=
L w/Pin,i i
Where:
CER = circulator energy rating hp;
wi = 0.25;
Pin,i = driver power input at each test point i hp; and i = test points corresponding to 25, 50, 75, and 100 percent of BEP flow.
FR Doc. 202125414 Filed 121721; 8:45 am
EP20DE21.041
BILLING CODE 645001P
VerDate Sep<11>2014
18:33 Dec 17, 2021
Jkt 256001
PO 00000
Frm 00050
Fmt 4701
Sfmt 9990
E:FRFM20DEP2.SGM
20DEP2
EP20DE21.040
khammond on DSKJM1Z7X2PROD with PROPOSALS2
Where:
CER = circulator energy rating hp;
wi = weight of 0.05, 0.40, 0.40, and 0.15 at test points of 25, 50, 75, and 100 percent of BEP flow, respectively;
Pin,i = driver power input at each test point i hp; and i = test points corresponding to 25, 50, 75, and 100 percent of BEP flow.
VI. Testing and Calculation of CER for Circulator Pumps Without External Input Signal, Manual, Pressure, or Temperature Controls Full Speed Test A. Scope.
A.1 This section VI applies only to circulator pumps sold without external input signal, manual, pressure, or temperature controls, or to any conduct of a full speed test.
B. Determination of circulator pump driver power input. At maximum speed of rotation, determine the driver power input at 25, 50, 75, and 100 percent of the measured BEP
flow rate as determined according to section I.E.2 of this appendix of the tested circulator pump in accordance with Appendix E of HI
40.62021.