Versione di testo Cosa è?Dateas è un sito indipendente non affiliato a entità governative. La fonte dei documenti PDF che pubblichiamo qui è l'entità governativa indicata in ciascuno di essi. Le versioni in testo sono trascrizioni che realizziamo per facilitare l'accesso e la ricerca di informazioni, ma possono contenere errori o non essere complete.
Source: Federal Register
69570
Federal Register / Vol. 86, No. 232 / Tuesday, December 7, 2021 / Proposed Rules
AxisD
AxisC
Axis A
AxisB
Test area
Figure 2 to Appendix U to Subpart B of Part 430: Testing Room and Sensor Arm Axes
four axes intersect, aligning the sensors perpendicular to the direction of airflow. Do not touch the actual sensor prior to testing.
Use enough sensors to record air delivery
6 Place the sensors at intervals of 4
0.0625 inches along a sensor arm, starting with the first sensor at the point where the
within a circle 8 inches larger in diameter than the blade span of the ceiling fan being tested. The experimental set-up is shown in Figure 3 of this appendix.
Ceiling Level
Lowest point on the blades Ceilin Fan
Unused sensors
43"
r
---1 I- 4,,
BILLING CODE 645001C
3.2.3. Multi-Head Ceiling Fan Test Set-Up.
Hang a multi-headed ceiling fan from the ceiling such that one of the ceiling fan heads is centered directly over sensor 1 i.e., at the
VerDate Sep<11>2014
19:07 Dec 06, 2021
Jkt 256001
intersection of axes A, B, C, and D. The distance between the lowest point any of the fan blades of the centered fan head can reach and the air velocity sensors is to be such that it is the same as for all other small-diameter ceiling fans see Figure 3 of this appendix.
PO 00000
Frm 00028
Fmt 4701
Sfmt 4702
If the multi-head ceiling fan has an oscillating function i.e., the fan heads change their axis of rotation relative to the ceiling that can be switched off, switch it off prior to taking air velocity measurements. If any multi-head fan does not come with the
E:FRFM07DEP4.SGM
07DEP4
EP07DE21.009
Figure 3 to Appendix U to Subpart B of Part 430: Air Delivery Room Set-Up for Small-Diameter Ceiling Fans other than High-Speed Belt-Driven Ceiling Fans
EP07DE21.008
lotter on DSK11XQN23PROD with PROPOSALS4
Sensor