Versione di testo Cosa è?Dateas è un sito indipendente non affiliato a entità governative. La fonte dei documenti PDF che pubblichiamo qui è l'entità governativa indicata in ciascuno di essi. Le versioni in testo sono trascrizioni che realizziamo per facilitare l'accesso e la ricerca di informazioni, ma possono contenere errori o non essere complete.

Source: Federal Register

68390

Federal Register / Vol. 86, No. 229 / Thursday, December 2, 2021 / Rules and Regulations TABLE 1.1SUMMARY OF ERRORS AND CORRECTIONSContinued CFR sections
Description of error and correction
Sections 4.2.5.1, 4.2.5.2, and 4.2.5.3 of appendix M; Sections 4.2.5.1, 4.2.5.2, and 4.2.5.3
of appendix M1;.
Section 4.2.5.1 of Appendix M; Section 4.2.5.1
of appendix M1.

Replaces cross-references to section 3.1.9
with 3.1.10.

Cross-references inadvertently not updated.

Changes subscript on left side of equation for energy E from hp to h by replacing hpTj with EhTj = EhpTj.
EhpTj = Q
Changes inequality for Case 2 of Section 4.2.5.1 to reflect intent consistent with Sections 4.2.5.2 and 4.2.5.3 by changing ToTj > Tcc to ToTj < Tcc.
Changes designation of booster stage capacity to use the correct superscript k=3 by ;hk=25 with Q
hk=35 where replacing Q
the text describes what test is used to obtain the booster stage 5 F capacity.
Changes the inequality in the equation of the title of Section 4.2.6.2 to be consistent with the text, Capacity Is Greater Than or Equal to the Building Heating Load. Replaces < with .
Changes the title to specify the correct compressor stage for the case, revising High to Booster, which is the k=3 compressor stage.
Inserts the word minimum missing in the definition for minimum-speed-limiting variable-speed heat pump to indicate which speed is higher than its value for operation in a 47 F ambient temperature.
Replaces incorrect cross-reference to Section 3.14.6 with 3.1.4.6.
Adds explicit description of the compressor speed to be used for the H42 5 F full-capacity heating mode test, consistent with the intent as described in the July 2016
SNOPR and January 2017 Final Rule preamble discussions.
Replaces the single instance of EER2 in the section with EER.
Removes extraneous in the title line of the section.

Transcription error.

Sections 4.2.5.1 of Appendix M; Section 4.2.5.1
of appendix M1.
Section 4.2.6.c of appendix M; Section 4.2.6.c of Appendix M1.

Section 4.2.6.2 of appendix M; Section 4.2.6.2
of appendix M1.

Section 4.2.6.3 of appendix M; Section 4.2.6.3
of appendix M1.
Section 1.2 of appendix M1

Section 3.1.4.7 of appendix M1
Paragraph d to section 3.6.4 Table 14 of appendix M1.

Section 4.1.4.2 of appendix M1
Section 4.1.3.2 of appendix M1

This document identifies and corrects these errors. Neither the errors nor the corrections in this document affect the substance of the rulemaking or any conclusions reached in support of the final rule.

lotter on DSK11XQN23PROD with RULES1

II. Need for Correction As published, the regulatory text in the January 2017 final rule may result in confusion due to incorrect symbols in the test procedure equations, typographical errors, incorrect crossreferences, and missing footnotes. The following sections provide the rationale for each correction. Because this final rule would correct errors in the text and provide additional detail without making substantive changes in the January 2017 final rule, the changes addressed in this document are technical in nature.

VerDate Sep<11>2014

16:00 Dec 01, 2021

Jkt 256001

A. Cross-References at 10 CFR
429.16a1
The January 2017 Final Rule added provisions for determining represented values for split systems in 10 CFR
429.16c3i but did not make corresponding edits to the crossreferences contained within 10 CFR
429.16a1, which describes the additional representations that are allowed for such systems i.e., in addition to the required representations. This document corrects this error by updating these cross-references.
B. Transcription Errors at 10 CFR
429.16f In the January 2017 Final Rule, DOE
established provisions for represented values required by the Federal Trade Commissionamong them the annual operating cost in cooling mode. These sections rely on the calculated quantities for cooling capacity and SEER

PO 00000

Frm 00002

Fmt 4700

Sfmt 4700

Rationale
Transcription error.

Transcription error. Booster capacity denoted as k=3 in all other locations throughout test procedure.
Incorrect inequality.

Transcription error. Booster capacity denoted as k=3 in all other locations throughout test procedure.
Transcription errormissing word minimum.

Transcription error.
Inadvertent omission of footnote.

Transcription error.
Transcription error.

in order to determine operating costs but contain incorrect cross-references to the sections where these quantities are calculated. This document corrects the cross-references to refer to the correct sections for represented values of cooling capacity and SEER as adopted by the January 2017 Final Rule.
C. Reference to H1N Test in Section 3.6.4
of Appendix M and Appendix M1
In the January 2017 Final rule, DOE
revised the requirement regarding compressor speed for the H1N heating mode test to allow the compressor speed used for the H1N test to be lower than used for the A2 test, provided that the H1N capacity is no lower than the A2 cooling capacity. 82 FR 1426, 1445.
However, in codifying this revision in section 3.6.4 of appendix M and section 3.6.4 of appendix M1, DOE did not properly incorporate the changes. In appendix M, DOE inadvertently referred to the H12 capacity instead of the H1N

E:FRFM02DER1.SGM

02DER1

Riguardo a questa edizione

Federal Register - December 2, 2021

TitoloFederal Register

PaeseStati Uniti

Data02/12/2021

Conteggio pagine152

Numero di edizioni7789

Prima edizione14/03/1936

Ultima edizione05/06/2026

Scarica questa edizione

Altre edizioni

<<<Diciembre 2021>>>
DLMMJVS
1234
567891011
12131415161718
19202122232425
262728293031