Versione di testo Cosa è?Dateas è un sito indipendente non affiliato a entità governative. La fonte dei documenti PDF che pubblichiamo qui è l'entità governativa indicata in ciascuno di essi. Le versioni in testo sono trascrizioni che realizziamo per facilitare l'accesso e la ricerca di informazioni, ma possono contenere errori o non essere complete.

Source: Federal Register

28473

Federal Register / Vol. 86, No. 101 / Thursday, May 27, 2021 / Rules and Regulations the material must be available to the public. All approved material is available for inspection at the U.S.
Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Sixth Floor, 950 LEnfant Plaza SW, Washington, DC 20024, 202 5862945, https www.energy.gov/eere/buildings/
appliance-and-equipment-standardsprogram, and may be obtained from the other sources in this section. It is also available for inspection at the National Archives and Records Administration NARA. For information on the availability of this material at NARA, email: fedreg.legal@nara.gov, or go to:
www.archives.gov/federal-register/cfr/
ibr-locations.html.
b
2 ANSI/AMCA Standard 20818, AMCA 20818, Calculation of the Fan Energy Index, ANSI approved January 24, 2018, IBR approved for appendix U to this subpart.

3. Appendix U to subpart B of part 430 is amended by:
a. Removing sections 1.1, 1.3, and 1.4;
b. Redesignating section 1.2 as 1.1;
c. Redesignating sections 1.5 through 1.23 as 1.2 through 1.20, respectively;
d. Revising section 3.5;
e. Revising the heading for section 4;
f. Removing the parenthetical for all tested settings for large-diameter ceiling fans in section 4.3;
g. Revising section 4.4; and h. Adding section 5.
The revisions and addition read as follows:
Appendix U to Subpart B of Part 430
Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans
jbell on DSKJLSW7X2PROD with RULES

3.5 Active mode test measurement for large-diameter ceiling fans:
1 Test large-diameter ceiling fans in accordance with ANSI/AMCA Standard 20818 in all phases simultaneously at:
a High speed, and b 40 percent speed or the nearest speed that is not less than 40 percent speed.
2 When testing at 40 percent speed for large-diameter ceiling fans that can operate over an infinite number of speeds e.g., ceiling fans with VFDs, ensure the average measured RPM is within the greater of 1% of the average RPM at high speed or 1 RPM. For example, if the average measured RPM
at high speed is 50 RPM, for testing at 40% speed, the average measured RPM
should be between 19 RPM and 21 RPM.
If the average measured RPM falls outside of this tolerance, adjust the
VerDate Sep<11>2014

16:44 May 26, 2021

Jkt 253001

ceiling fan speed and repeat the test.
Calculate the airflow and measure the active real power consumption in all phases simultaneously in accordance with the test requirements specified in sections 8 and 9, AMCA 23015
incorporated by reference, see 430.3, with the following modifications:

4. Calculation of Ceiling Fan Efficiency From the Test Results for LSSD and HSSD ceiling fans:

4 Table 3 of this appendix specifies the daily hours of operation to be used in calculating ceiling fan efficiency:

TABLE 3 TO APPENDIX U TO SUBPART
B OF PART 430: DAILY OPERATING
HOURS FOR CALCULATING CEILING
FAN EFFICIENCY
No standby
3.4
3.0
0.0
17.6

3.4
3.0
17.6
0.0

Daily Operating Hours for HSSD Ceiling Fans High Speed
Standby Mode
Off Mode

12.0
0.0
12.0

12.0
12.0
0.0

5. Calculation of Ceiling Fan Energy Index CFEI From the Test Results for Large-Diameter Ceiling Fans:
Calculate CFEI, which is the FEI for large-diameter ceiling fans, at the speeds specified in section 3.5 of this appendix according to ANSI/AMCA 20818, incorporated by reference, see 430.3, with the following modifications:
1 Using an Airflow Constant Q0 of 26,500 cubic feet per minute;
2 Using a Pressure Constant P0 of 0.0027 inches water gauge; and 3 Using a Fan Efficiency Constant h0 of 42 percent.
4. Section 430.32 is amended by:
a. Revising paragraph s2i;
b. Redesignating s2ii as s2iii;
and c. Adding new paragraph s2ii.
The revision and addition read as follows:
430.32 Energy and water conservation standards and their compliance dates.

s
2i Ceiling fans manufactured on or after January 21, 2020, shall meet the requirements shows in the table:

PO 00000

Frm 00005

Fmt 4700

Sfmt 4700

Minimum efficiency CFM/W 1

Very small-diameter VSD

D 12 in.: 21.
D > 12 in.: 3.16
D17.04.
0.65 D + 38.03.
0.29 D + 34.46.
4.16 D + 0.02.

Standard
Hugger
High-speed small-diameter HSSD.

1 D is the ceiling fans blade span, in inches, as determined in Appendix U of this part.

ii Large-diameter ceiling fans manufactured on or after January 21, 2020, shall have a CFEI greater than or equal to A 1.00 at high speed; and B 1.31 at 40 percent speed or the nearest speed that is not less than 40
percent speed.

FR Doc. 202110882 Filed 52621; 8:45 am BILLING CODE 645001P

With standby
Daily Operating Hours for LSSD Ceiling Fans High Speed
Low Speed
Standby Mode
Off Mode

Product class as defined in Appendix U

DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration 14 CFR Part 39
Docket No. FAA200626107; Project Identifier 2004SW30AD; Amendment 39
21549; AD 20211016
RIN 2120AA64

Airworthiness Directives; Carson Helicopters, Inc.; Croman Corporation;
Sikorsky Aircraft Corporation; and Siller Helicopters Federal Aviation Administration FAA, DOT.
ACTION: Final rule.
AGENCY:

The FAA is adopting a new airworthiness directive AD for all Carson Helicopters, Inc., Model S61L
and SH3H helicopters; Croman Corporation Model SH3H helicopters;
Sikorsky Aircraft Corporation Model S61A, S61D, S61E, and S61V
helicopters; and Siller Helicopters Model CH3E and SH3A helicopters.
This AD was prompted by an accident.
This AD requires tracking hours time-inservice TIS and external lift cycles lift cycles for certain main gearbox left and right input freewheel unit IFWU
assemblies. This AD also requires determining the type of IFWU assembly installed and depending on the results, calculating the moving average, repetitive inspections, recording certain information, replacing parts, and marking parts. The FAA is issuing this AD to address the unsafe condition on these products.
DATES: This AD is effective July 1, 2021.
SUMMARY:

E:FRFM27MYR1.SGM

27MYR1

Riguardo a questa edizione

Federal Register - May 27, 2021

TitoloFederal Register

PaeseStati Uniti

Data27/05/2021

Conteggio pagine228

Numero di edizioni7798

Prima edizione14/03/1936

Ultima edizione18/06/2026

Scarica questa edizione

Altre edizioni

<<<Mayo 2021>>>
DLMMJVS
1
2345678
9101112131415
16171819202122
23242526272829
3031