Federal Register - May 19, 2021
Versione di testo Cosa è?Dateas è un sito indipendente non affiliato a entità governative. La fonte dei documenti PDF che pubblichiamo qui è l'entità governativa indicata in ciascuno di essi. Le versioni in testo sono trascrizioni che realizziamo per facilitare l'accesso e la ricerca di informazioni, ma possono contenere errori o non essere complete.
Source: Federal Register
khammond on DSKJM1Z7X2PROD with RULES2
Federal Register / Vol. 86, No. 95 / Wednesday, May 19, 2021 / Rules and Regulations
27259
2 Except where noted in this Table II and the method for the parameter, preserve each grab sample within 15 minutes of collection. For a composite sample collected with an automated sample e.g., using a 24-hour composite sample; see 40 CFR 122.21g7i or 40 CFR part 403, appendix E, refrigerate the sample at 6 C during collection unless specified otherwise in this Table II or in the methods. For a composite sample to be split into separate aliquots for preservation and/or analysis, maintain the sample at 6 C, unless specified otherwise in this Table II or in the methods, until collection, splitting, and preservation is completed. Add the preservative to the sample container prior to sample collection when the preservative will not compromise the integrity of a grab sample, a composite sample, or aliquot split from a composite sample within 15
minutes of collection. If a composite measurement is required but a composite sample would compromise sample integrity, individual grab samples must be collected at prescribed time intervals e.g., 4 samples over the course of a day, at 6-hour intervals. Grab samples must be analyzed separately and the concentrations averaged. Alternatively, grab samples may be collected in the field and composited in the laboratory if the compositing procedure produces results equivalent to results produced by arithmetic averaging of results of analysis of individual grab samples. For examples of laboratory compositing procedures, see EPA Method 1664 Rev. A oil and grease and the procedures at 40 CFR
141.24f14iv and v volatile organics.
3 When any sample is to be shipped by common carrier or sent via the U.S. Postal Service, it must comply with the Department of Transportation Hazardous Materials Regulations 49 CFR part 172. The person offering such material for transportation is responsible for ensuring such compliance. For the preservation requirement of Table II, the Office of Hazardous Materials, Materials Transportation Bureau, Department of Transportation has determined that the Hazardous Materials Regulations do not apply to the following materials: Hydrochloric acid HCl in water solutions at concentrations of 0.04% by weight or less pH about 1.96 or greater; Nitric acid HNO3 in water solutions at concentrations of 0.15%
by weight or less pH about 1.62 or greater; Sulfuric acid H2SO4 in water solutions at concentrations of 0.35% by weight or less pH about 1.15 or greater; and Sodium hydroxide NaOH in water solutions at concentrations of 0.080% by weight or less pH about 12.30 or less.
4 Samples should be analyzed as soon as possible after collection. The times listed are the maximum times that samples may be held before the start of analysis and still be considered valid. Samples may be held for longer periods only if the permittee or monitoring laboratory have data on file to show that, for the specific types of samples under study, the analytes are stable for the longer time, and has received a variance from the Regional ATP Coordinator under 136.3e. For a grab sample, the holding time begins at the time of collection. For a composite sample collected with an automated sampler e.g., using a 24-hour composite sampler; see 40 CFR 122.21g7i or 40 CFR part 403, appendix E, the holding time begins at the time of the end of collection of the composite sample. For a set of grab samples composited in the field or laboratory, the holding time begins at the time of collection of the last grab sample in the set. Some samples may not be stable for the maximum time period given in the table. A permittee or monitoring laboratory is obligated to hold the sample for a shorter time if it knows that a shorter time is necessary to maintain sample stability. See 136.3e for details. The date and time of collection of an individual grab sample is the date and time at which the sample is collected. For a set of grab samples to be composited, and that are all collected on the same calendar date, the date of collection is the date on which the samples are collected. For a set of grab samples to be composited, and that are collected across two calendar dates, the date of collection is the dates of the two days; e.g., November 1415. For a composite sample collected automatically on a given date, the date of collection is the date on which the sample is collected. For a composite sample collected automatically, and that is collected across two calendar dates, the date of collection is the dates of the two days; e.g., November 1415. For static-renewal toxicity tests, each grab or composite sample may also be used to prepare test solutions for renewal at 24 h, 48 h, and/or 72 h after first use, if stored at 0
6 C, with minimum head space.
5 ASTM D736509a specifies treatment options for samples containing oxidants e.g., chlorine for cyanide analyses. Also, Section 9060A of Standard Methods for the Examination of Water and Wastewater 23rd edition addresses dechlorination procedures for microbiological analyses.
6 Sampling, preservation and mitigating interferences in water samples for analysis of cyanide are described in ASTM D736509a 15. There may be interferences that are not mitigated by the analytical test methods or D736509a 15. Any technique for removal or suppression of interference may be employed, provided the laboratory demonstrates that it more accurately measures cyanide through quality control measures described in the analytical test method. Any removal or suppression technique not described in D736509a 15 or the analytical test method must be documented along with supporting data.
7 For dissolved metals, filter grab samples within 15 minutes of collection and before adding preservatives. For a composite sample collected with an automated sampler e.g., using a 24-hour composite sampler; see 40 CFR 122.21g7i or 40 CFR part 403, appendix E, filter the sample within 15 minutes after completion of collection and before adding preservatives. If it is known or suspected that dissolved sample integrity will be compromised during collection of a composite sample collected automatically over time e.g., by interchange of a metal between dissolved and suspended forms, collect and filter grab samples to be composited footnote 2 in place of a composite sample collected automatically.
8 Guidance applies to samples to be analyzed by GC, LC, or GC/MS for specific compounds.
9 If the sample is not adjusted to pH 2, then the sample must be analyzed within seven days of sampling.
10 The pH adjustment is not required if acrolein will not be measured. Samples for acrolein receiving no pH adjustment must be analyzed within 3 days of sampling.
11 When the extractable analytes of concern fall within a single chemical category, the specified preservative and maximum holding times should be observed for optimum safeguard of sample integrity i.e., use all necessary preservatives and hold for the shortest time listed. When the analytes of concern fall within two or more chemical categories, the sample may be preserved by cooling to 6 C, reducing residual chlorine with 0.008% sodium thiosulfate, storing in the dark, and adjusting the pH to 69; samples preserved in this manner may be held for seven days before extraction and for forty days after extraction. Exceptions to this optional preservation and holding time procedure are noted in footnote 5
regarding the requirement for thiosulfate reduction, and footnotes 12, 13 regarding the analysis of benzidine.
12 If 1,2-diphenylhydrazine is likely to be present, adjust the pH of the sample to 4.0 0.2 to prevent rearrangement to benzidine.
13 Extracts may be stored up to 30 days at <0 C.
14 For the analysis of diphenylnitrosamine, add 0.008% Na S O and adjust pH to 710 with NaOH within 24 hours of sampling.
2 2 3
15 The pH adjustment may be performed upon receipt at the laboratory and may be omitted if the samples are extracted within 72 hours of collection. For the analysis of aldrin, add 0.008% Na2S2O3.
16 Place sufficient ice with the samples in the shipping container to ensure that ice is still present when the samples arrive at the laboratory.
However, even if ice is present when the samples arrive, immediately measure the temperature of the samples and confirm that the preservation temperature maximum has not been exceeded. In the isolated cases where it can be documented that this holding temperature cannot be met, the permittee can be given the option of on-site testing or can request a variance. The request for a variance should include supportive data which show that the toxicity of the effluent samples is not reduced because of the increased holding temperature. Aqueous samples must not be frozen. Hand-delivered samples used on the day of collection do not need to be cooled to 0 to 6 C prior to test initiation.
17 Samples collected for the determination of trace level mercury <100 ng/L using EPA Method 1631 must be collected in tightly-capped fluoropolymer or glass bottles and preserved with BrCl or HCl solution within 48 hours of sample collection. The time to preservation may be extended to 28 days if a sample is oxidized in the sample bottle. A sample collected for dissolved trace level mercury should be filtered in the laboratory within 24 hours of the time of collection. However, if circumstances preclude overnight shipment, the sample should be filtered in a designated clean area in the field in accordance with procedures given in Method 1669. If sample integrity will not be maintained by shipment to and filtration in the laboratory, the sample must be filtered in a designated clean area in the field within the time period necessary to maintain sample integrity. A sample that has been collected for determination of total or dissolved trace level mercury must be analyzed within 90 days of sample collection.
18 Aqueous samples must be preserved at 6 C, and should not be frozen unless data demonstrating that sample freezing does not adversely impact sample integrity is maintained on file and accepted as valid by the regulatory authority. Also, for purposes of NPDES monitoring, the specification of C is used in place of the 4 C and <4 C sample temperature requirements listed in some methods. It is not necessary to measure the sample temperature to three significant figures 1/100th of 1 degree; rather, three significant figures are specified so that rounding down to 6 C may not be used to meet the 6 C requirement. The preservation temperature does not apply to samples that are analyzed immediately less than 15 minutes.
VerDate Sep<11>2014
17:42 May 18, 2021
Jkt 253001
PO 00000
Frm 00035
Fmt 4701
Sfmt 4700
E:FRFM19MYR2.SGM
19MYR2