Versione di testo Cosa è?Dateas è un sito indipendente non affiliato a entità governative. La fonte dei documenti PDF che pubblichiamo qui è l'entità governativa indicata in ciascuno di essi. Le versioni in testo sono trascrizioni che realizziamo per facilitare l'accesso e la ricerca di informazioni, ma possono contenere errori o non essere complete.

Source: Federal Register

Federal Register / Vol. 86, No. 47 / Friday, March 12, 2021 / Rules and Regulations generator and the generator voltage regulator regulator. The FAA is issuing this AD to address loss of electrical ground between the starter-generator and the regulator. This condition could result in an overvoltage of electrical power, damage to electronic equipment, and subsequent loss of control of the helicopter.
f Compliance Comply with this AD within the compliance times specified, unless already done.
g Required Actions 1 Within 50 hours time-in-service TIS:
i Visually inspect the wire terminal of wire P55F16N/P56F16N for Model BO105A, BO105C, and BO105S helicopters and wire 1PA53B20/2PA53B20 for Model MBBBK
117 A1, MBBBK 117 A3, MBBBK 117
A4, MBBBK 117 B1, MBBBK 117 B2, and MBBBK 117 C1 helicopters on Terminal E of each starter-generator for a crack, a kink, fraying, looseness, missing material, and corrosion. If there is a crack, a kink, fraying, looseness, missing material, or any corrosion, before further flight, replace the wire terminal.

VerDate Sep<11>2014

19:32 Mar 11, 2021

Jkt 253001

ii Measure the resistance between each starter-generator and its regulator in accordance with the Accomplishment Instructions, paragraph 2.A.2.3. of Eurocopter Alert Service Bulletin ASB BO10590103, Revision 4, dated June 21, 2010, or paragraphs 2.A.2.3. and 2.A.2.5. of Eurocopter Alert Service Bulletin ASB
MBBBK11790118, Revision 2, dated May 4, 2009, as applicable to your model helicopter. If the resistance is more than 500
milliohms, before further flight, replace the wire terminal.
2 Within 150 hours TIS:
i Install a wire harness from each generator voltage regulator as follows.
A For Model BO105A, BO105C, and BO105S helicopters: Wire harness P/N 105
90081.
B For Model MBBBK 117 A1, MBBBK
117 A3, MBBBK 117 A4, MBBBK 117 B
1, and MBBBK 117 B2 helicopters: Wire harness P/N 117901941.
C For Model MBBBK 117 C1
helicopters: Wire harness P/N 117901961.
ii For Model MBBBK 117 A3, MBBBK
117 A4, MBBBK 117 B1, MBBBK 117 B
2, and MBBBK 117 C1 helicopters, revise
PO 00000

Frm 00007

Fmt 4700

Sfmt 4700

13977

the existing Rotorcraft Flight Manual RFM
for your helicopter to include the information in Section 3 Emergency and Malfunction Procedures of the following temporary revisions, as applicable to your helicopter:
Eurocopter Flight Manual BK117 A3
Temporary Revision 9, Eurocopter Flight Manual BK117 A4 Temporary Revision 5, Eurocopter Flight Manual BK117 B1
Temporary Revision 6, Eurocopter Flight Manual BK 117 B2 Temporary Revision 1, or Eurocopter Flight Manual BK 117 C1
Temporary Revision 2, all dated September 22, 2006. Using a later RFM revision with information identical to that contained in the temporary revision specified for your helicopter is acceptable for compliance with the requirement of this paragraph.
iii For Model MBBBK 117 A1
helicopters, revise Section 3 Emergency and Malfunction Procedures of the existing RFM
for your helicopter to include the information in Figures 1 through 3 to paragraph g2iii of this AD.
BILLING CODE 491013P

E:FRFM12MRR1.SGM

12MRR1

Riguardo a questa edizione

Federal Register - March 12, 2021

TitoloFederal Register

PaeseStati Uniti

Data12/03/2021

Conteggio pagine259

Numero di edizioni7798

Prima edizione14/03/1936

Ultima edizione18/06/2026

Scarica questa edizione

Altre edizioni

<<<Marzo 2021>>>
DLMMJVS
123456
78910111213
14151617181920
21222324252627
28293031