Versione di testo Cosa è?Dateas è un sito indipendente non affiliato a entità governative. La fonte dei documenti PDF che pubblichiamo qui è l'entità governativa indicata in ciascuno di essi. Le versioni in testo sono trascrizioni che realizziamo per facilitare l'accesso e la ricerca di informazioni, ma possono contenere errori o non essere complete.
Source: Federal Register
Federal Register / Vol. 86, No. 7 / Tuesday, January 12, 2021 / Rules and Regulations 3280.705
The water used for the test must be obtained from a potable water source.
26. Amend 3280.705 by:
a. Revising paragraph c1;
b. In paragraph j, removing shall and add in its place must wherever it appears;
c. Revising paragraphs k, l7, and l8i; and d. Adding paragraph l8iii.
The revisions and addition to read as follows:
c
1 All points of crossover beneath the transportable sections must be readily accessible from the exterior of the home.
In multi-story manufactured homes, the interconnections between stories must be accessible through a panel on the exterior or interior of the manufactured home.
k Identification of gas supply connections. Each manufactured home must have permanently affixed to the
l
7 Hangers and supports. All horizontal gas piping must be adequately supported by galvanized or equivalently protected metal straps or hangers at intervals of not more than 4
feet, except where adequate support and protection is provided by structural members. Vertical gas piping in multistory dwelling units must be supported at intervals of not more than 6 feet.
Solid iron-pipe connections must be rigidly anchored to a structural member within 6 inches of the supply connections.
8 i Before appliances are connected, piping systems must stand a pressure of three 0.2 psi gauge for a period of not less than ten minutes without showing any drop in pressure.
Pressure must be measured with a mercury manometer or slope gauge calibrated so as to be read in increments of not greater than one-tenth pound, or an equivalent device. The source of normal operating pressure must be isolated before the pressure tests are made. Before a test is begun, the temperature of the ambient air and of the piping must be approximately the same, and constant air temperature must be maintained throughout the test.
iii Where gas piping between transportable sections must be made on site, the installation instructions must contain provisions for onsite testing for leakage consistent with the provisions in paragraph l8i of this section.
khammond on DSKJM1Z7X2PROD with RULES2
Gas piping systems.
VerDate Sep<11>2014
17:18 Jan 11, 2021
Jkt 253001
PO 00000
Frm 00028
Fmt 4701
Sfmt 4700
exterior skin at or near each gas supply connection or the end of the pipe, a tag of 3 inches by 134 inches minimum size, made of etched, metal-stamped or embossed brass, stainless steel, anodized or alcalde aluminum not less than 0.020 inch thick, or other approved material e.g., 0.005 inch plastic laminates, with the information shown in Figure 1 to this paragraph k. The connector capacity indicated on this tag must be equal to or greater than the total Btu/hr rating of all intended gas appliances.
27. In 3280.708, revise paragraph a1 introductory text to read as follows:
3280.708 Exhaust duct system and provisions for the future installation of a clothes dryer.
a 1 All gas and electric clothes dryers must be exhausted to the outside by a moisture/lint exhaust duct and termination fitting. When the manufacturer supplies the clothes dryer, the exhaust duct and termination fittings must be completely installed by the manufacturer. If the exhaust duct system is subject to damage during transportation, or a field connection between transportable sections is required, complete factory installation